916 945 561 · empresa@faytexsl.comMy areaSuggestion boxES · EN · FR · PT
Request a quote

Sandwich panel roofs and façades

Fixing roof and wall sandwich panels to steel purlins, rolled beams, concrete or timber, with double-thread screws that hold the outer sheet without crushing the core.

Where it is used. Industrial, logistics and agri-food buildings with roof (profiled) or wall sandwich panels on steel, concrete or timber structures.

3D illustration: sandwich panel roofs and façades

How to install

  1. Lay each panel with the side lap facing away from the prevailing wind and align the ribs.
  2. Fix through the rib crown at each purlin with a panel screw: the secondary thread under the head holds the outer sheet.
  3. Choose the drill point for the substrate: no. 3 for steel up to 5 mm, no. 5 for rolled sections up to 10 mm; on concrete or timber, FYTHOR DR.
  4. Tighten until the EPDM washer is compressed without being deformed. In high-wind areas, add a clip or capelotti to improve pull-through resistance.
  5. Stitch side laps every 30-50 cm with a stitching screw or sealed rivet.
  6. In aggressive environments (coastal, chemical industry) switch to bi-metal, stainless steel or Delta FYT coating.
Installation diagram: sandwich panel on cold-formed steel purlin
Sandwich panel on cold-formed steel purlin

Recommended fasteners

Data sheets and DoPs →

Guidance only. The type, length and number of fasteners depend on the project, the substrate and the wind uplift calculation; please consult us for each project.

Other solutions