916 945 561 · empresa@faytexsl.comMy areaSuggestion boxES · EN · FR · PT
Request a quote

Deck roofs on timber decks

Fastening insulation and membrane to timber or OSB decks with S-point EDS-H screws, on their own or with a telescopic sleeve.

Where it is used. Flat roofs on timber decks, cross-laminated timber (CLT) panels or OSB boards on joists.

3D illustration: Deck roofs on timber decks

How to install

  1. Lay the vapour barrier and the insulation boards staggered on the deck.
  2. Fix each insulation board with 6 fasteners: 4 at the corners and 2 in the centre.
  3. Fix the membrane at the lap with a TLK or TRP sleeve and EDS-H screw, or with an EDS-H screw and stress plate.
  4. The screw must engage at least 18 mm into the timber.
  5. Lap the next sheet over and weld it.
Installation diagram: TLKH-45 system on timber deck
TLKH-45 system on timber deck
Installation diagram: EDS-H screw with stress plate
EDS-H screw with stress plate

Recommended fasteners

Data sheets and DoPs →

Guidance only. The type, length and number of fasteners depend on the project, the substrate and the wind uplift calculation; please consult us for each project.