Deck roofs on steel deck
Mechanical fastening of insulation and waterproofing membrane (PVC, TPO, EPDM or bituminous) to steel deck, with telescopic sleeve + screw systems or screws with stress plates.
Where it is used. Large flat roofs (logistics, industry, shopping centres) on 0.6 to 1.25 mm steel deck, with PIR or mineral wool insulation.

How to install
- Lay the vapour barrier and place the insulation boards staggered on the deck crowns.
- Fix each insulation board with 6 fasteners: 4 at the corners and 2 in the centre.
- Lay the waterproofing membrane and fix it along the lap edge with the chosen fastener: telescopic sleeve + screw or screw + stress plate.
- Always screw into the deck crown; the screw must pass through the deck by at least 20 mm.
- With a sleeve, the screw sits fully inside it; choose the length from the table on the product page according to the insulation thickness.
- Lap the next sheet over the fasteners and weld it. The number and layout of fasteners come from the wind uplift calculation.

Recommended fasteners
Data sheets and DoPs →Sleeve + screw systems
Screw + stress plate
Deck FYT EDS-B 4,84.8 mm diameter screw for fixing to steel deck min. 0.70 mm / max. 2x1.25 mm, Torx 25 head.
Deck FYT EDS-S 4,84.8 mm diameter screw for fixing to steel deck min. 0.60 mm / max. 0.88 mm, PH2 head.
Deck FYT EDS-BZT 4,84.8 mm diameter screw, loose or collated for the Deckfix machine, for fixing to steel deck min. 0.70 mm / max. 2x1.25 mm, 8 mm hexagon head.
Deck FYT PLATE RED CE 5050 mm round stress plate
Deck FYT PLATE OVAL CE 80x4080x40 oval stress plate, CEMachine installation
Insulation
Guidance only. The type, length and number of fasteners depend on the project, the substrate and the wind uplift calculation; please consult us for each project.