Profiled sheet roofs and façades

Fixing single-skin profiled or corrugated sheets to steel, timber or concrete purlins and beams, and watertight stitching of side laps.

Where it is used. Single-skin sheet roofs and walls on industrial buildings, sheds, canopies and refurbishments, including fibre cement replacement.

3D illustration: profiled sheet roofs and façades

How to install

  1. Fix in the crown or in the valley, but always with a washer.
  2. Use self-drilling screws with EPDM washers: no. 3 drill point for steel up to 5 mm and no. 5 for beams up to 12.5 mm.
  3. On timber, use RCH MAD or reduced-point screws. On concrete, use FYTHOR screws.
  4. Stitch side laps with a no. 1 point screw or a sealed rivet every 30-50 cm.
  5. In aggressive environments (coastal, chemical industry) switch to bi-metal, stainless steel or Delta FYT coating.
Installation diagram: sheet on cold-formed steel purlin
Sheet on cold-formed steel purlin
Installation diagram: sheet on hot-rolled steel beam
Sheet on hot-rolled steel beam

Recommended fasteners

Data sheets and DoPs →

Guidance only. The type, length and number of fasteners depend on the project, the substrate and the wind uplift calculation; please consult us for each project.